| MODEL | CLPS60-W1V12 | CLPS60-W1V24 | |||||||
| OUTPUT | RATED VOLTAGE | 12V | 24V | ||||||
| NO-LOAD VOLTAGE(MAX.) | 12.6V | 25.2V | |||||||
| VOLTAGE TOLERANCE | ±5% | ±5% | |||||||
| RATED CURRENT | 5A | 2.5A | |||||||
| CURRENT RANGE | 0-5A | 0-2.5A | |||||||
| RATED POWER | 60W | 60W | |||||||
| RIPPLE& NOISE (MAX.) | 120mVp-p | 150mVp-p | |||||||
| POWER FACTOR(Typ.) | 0.6 | 0.6 | |||||||
| INPUT | VOLTAGE RANGE | 100-240VAC | |||||||
| FREQUENCY RANGE | 50-60 Hz | ||||||||
| AC CURRENT(Typ.) | 1.02A/115V, 0.51A/230V | ||||||||
| EFFICIENCY(Typ.) | 88% | 89% | |||||||
| COLD START CURRENT | 30A/AC220V | ||||||||
| SETUP, RISE, HOLD UP TIME | 2000ms, 100ms, 30ms | ||||||||
| NO-LOAD CURRENT | <50mA/240VAC | ||||||||
| PROTECTION | OVER LOAD | hiccup 115%~135% of the rated power 60W, | |||||||
| recovers automatically after fault condition is removed | |||||||||
| OVER CURRENT | protected over the maximum rated current, | ||||||||
| recovers automatically after fault condition is removed | |||||||||
| SHORT CIRCUIT | hiccup short circuit, | ||||||||
| recovers automatically after fault condition is removed | |||||||||
| OVER TEMP | protected when the Rectifier ≥105°C, | ||||||||
| recovers automatically after temperature fall to environment temp | |||||||||
| ENVIRONMENT | WORKING TEMP&HUMIDITY | –20°C~+60°C (no frost), 20%~90%RH | |||||||
| STORAGE TEMP&HUMIDITY | –40°C~85°C, 10%~95%RH | ||||||||
| SEISMIC CAPACITY | 10-500Hz 2G 10.min/1 60min | ||||||||
| WITHSTAND VOLTAGE | I/P-O/P: 1.5KVAC/1min, I/P-F/G: 1.5KVAC/1min, O/P-F/G: 0.5KVAC/1min, | ||||||||
| INSULATION RESISTANCE | 100M ohm s/DC500V | ||||||||
| SAFETY&EMC | SAFETY STANDARDS | GB4943 ;IEC60950-1; EN60950-1 | |||||||
| EMC STANDARDS | EN55022 CLASS A;GB9254 | ||||||||
| REMARK | 1. The above mentioned data were measured at 220VAC input and 25°C. | ||||||||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated | |||||||||
| with a 0.1uf & 47uf parallel capacitor. | |||||||||