| MAQUETTE | 12V 200W | 24V 200W | |||
| PRODUCTION | TENSION CONTINUE | 12V | 24V | ||
| COURANT NOMINAL | 16.6A | 8.33A | |||
| GAMME ACTUELLE | 0~16.6A | 0~8.33A | |||
| PUISSANCE NOMINALE | 200W | 200W | |||
| ONDULATION ET BRUIT (MAX.) | 120mVp-p | 150mVp-p | |||
| TOLÉRANCE DE TENSION | ±1% | ±1% | |||
| CONFIGURATION, TEMPS DE MONTÉE | 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC à pleine charge | ||||
| TEMPS D’ATTENTE (Typ.) | 20ms/230VAC 16ms/115VAC à pleine charge | ||||
| CONTRIBUTION | PLAGE DE TENSION | 85~132VAC/170~264VAC | |||
| GAMME DE FRÉQUENCES | 47~63Hz | ||||
| FACTEUR DE PUISSANCE (Typ.) | PF> 0.6/220VAC | ||||
| EFFICACITÉ(Typ.) | 85% | 86% | |||
| COURANT AC (Typ.) | 3.5A/115VAC 1.8A/230VAC | ||||
| COURANT D’APPEL (Typ.) | 50A/230VAC | ||||
| COURT-CIRCUIT | type de protection: récupère automatiquement après la suppression de la condition de défaut | ||||
| PROTECTION | SURCHARGE | 105 ~ 135% mode hoquet, récupération automatique | |||
| SURTEMPERATURE | 85°C protection de démarrage, récupère automatiquement | ||||
| DC ADJ. INTERVALLE | 115%~135% Couper la sortie, récupération automatique | ||||
| ENVIRONNEMENT | TEMP DE TRAVAIL | -20℃~ +60℃ | |||
| HUMIDITÉ DE TRAVAIL | 20%~90% humidité relative | ||||
| TEMPÉRATURE DE STOCKAGE, HUMIDITÉ | -40℃~+85℃,10 %~90% HR | ||||
| SÉCURITÉ et CEM | LES NORMES DE SÉCURITÉ | CE, ROHS | |||
| TENSION DE TENUE | I/PO/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| NORME DE TEST CEM | EN55015:2006;EN61547:1995+A1:2000;EN61000-3-2:2006; | ||||
| EN61000-3-3:1995+A2:2005;EN61347-1:2001;EN61347-2-13:2006 | |||||