| MAQUETTE | 12V 500W | 15V 500W | 24V 500W | 27V 500W | 48V 500W | |
| PRODUCTION | TENSION CONTINUE | 12V | 15V | 24V | 27V | 48V |
| COURANT NOMINAL | 41,6A | 33.3A | 20.83A | 18.5A | 10.42A | |
| GAMME ACTUELLE | 0~41,6A | 0~33.3A | 0~20.83A | 0~18.5A | 0~10.42A | |
| PUISSANCE NOMINALE | 500W | 500W | 500W | 500W | 500W | |
| ONDULATION ET BRUIT (MAX.) | 150mVc-c | 150mVc-c | 150mVc-c | 150mVc-c | 200mV | |
| TOLÉRANCE DE TENSION | ±1% | ±1% | ±1% | ±1% | ±1% | |
| CONFIGURATION, TEMPS DE MONTÉE | 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC à pleine charge | |||||
| TEMPS D’ATTENTE (Typ.) | 20ms/230VAC 16ms/115VAC à pleine charge | |||||
| CONTRIBUTION | PLAGE DE TENSION | 85~132VAC/170~264VAC | ||||
| GAMME DE FRÉQUENCES | 47~63Hz | |||||
| FACTEUR DE PUISSANCE (Typ.) | PF> 0.6/220VAC | |||||
| EFFICACITÉ(Typ.) | 80% | 82% | 82% | 83% | 84% | |
| COURANT AC (Typ.) | 7A/115VAC 4A/230VAC | |||||
| COURANT D’APPEL (Typ.) | 40A/115VAC 60A/230VAC | |||||
| COURT-CIRCUIT | type de protection: récupère automatiquement après la suppression de la condition de défaut | |||||
| PROTECTION | SURCHARGE | 105 ~ 135% mode hoquet, récupération automatique | ||||
| SURTEMPERATURE | type de protection: récupère automatiquement après une température inférieure à 85°C | |||||
| DC ADJ. INTERVALLE | 115%~135% Couper la sortie, récupération automatique | |||||
| ENVIRONNEMENT | TEMP DE TRAVAIL | -20℃~ +60℃ | ||||
| HUMIDITÉ DE TRAVAIL | 20%~90% humidité relative | |||||
| TEMPÉRATURE DE STOCKAGE, HUMIDITÉ | -40℃~+85℃,10 %~90% HR | |||||
| SÉCURITÉ et CEM | LES NORMES DE SÉCURITÉ | CE, ROHS | ||||
| TENSION DE TENUE | I/PO/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
| NORME DE TEST CEM | EN55015:2006;EN61547:1995+A1:2000;EN61000-3-2:2006; | |||||
| EN61000-3-3:1995+A2:2005;EN61347-1:2001;EN61347-2-13:2006 | ||||||